Home / Products

NSA-series Smart Station Monitoring Units

Box-type transformer measurement, control and protection for solar and wind plants. All options are configurable per project; final configuration follows the project drawings.

NSA3 — with cable health monitoring

  • Box transformer telemetry, status, remote control, protection and event recording (10 waveforms, 500 SOE).
  • Communication gateway: up to 8 RS-485 master ports and 4 Ethernet ports for inverters, combiner boxes, meters and cameras.
  • Two fiber ports form a self-healing ring; ST connectors, up to 50 km.
  • Cable sheath grounding-current monitoring with trend analysis and alarms.
  • Wireless (433 MHz) cable-joint temperature sensing with configurable thresholds.
  • PCCC product certification to DL/T 478-2013 and GB/T 7261-2016.

NSA2 — multi-device communication management

  • Continuous monitoring of the box transformer with telemetry, status, remote control, protection and recording.
  • Up to 8 RS-485 master ports and 4 Ethernet ports to integrate inverters, combiner boxes, meters and environmental monitors.
  • Self-healing fiber ring with two ST fiber ports; optional Wi-Fi access point.

NSA6000 — compact and rugged

  • High-performance EMC design for harsh field conditions; LED display of transformer voltages and currents.
  • Overcurrent stages I/II/III, ground fault, overvoltage, undervoltage and non-electrical protections; 500 fault records.
  • Uplink by fiber, Ethernet or RS-485 to suit each site; HMI (RS-485) service port.

Configuration overview

ItemNSA3NSA2NSA6000
AC input groups (3-phase V/I)332
DC inputs (PT100 / 4–20 mA)6 total6 total6 total
Grounding-current input1——
Digital inputs404040
Digital (relay) outputs101010
Fiber ports22Optional
Ethernet ports44
RS-485 master ports88
433 MHz wireless receiverYes——
ProtectionElectrical and non-electrical
Records500

Maximum configurations; all items are optional and follow the project drawings.

Technical specifications (all models)

Current input
5 A or 1 A; accuracy class 0.5
Voltage input
AC 690 V / 400 V / 100 V; accuracy class 0.5
Frequency
50 Hz or 60 Hz; ±0.02 Hz
Power / power factor
±1%
Digital inputs
AC/DC 220 V, opto-isolated with surge absorption, insulation ≥ AC 1500 V
Relay outputs
AC 220 V 8 A; AC 380 V 1.9 A; DC 250 V 1.5 A; > 100,000 operations
Communication
Fiber (ST, up to 50 km), 10/100Base-TX Ethernet, RS-485
Protocols
MODBUS-RTU, IEC 60870-5-103/104, IEC 61850
Power supply
AC/DC 220 V ±20%, 50 Hz (−6%…+2%), ≤ 10 W
Operating temperature
−40 °C to +70 °C
Humidity / pressure
Max. 90% monthly average RH, non-condensing; 80–110 kPa
EMC
GB/T 14598 (IEC 60255-22/-25) series: ESD, oscillatory wave, radiated RF, EFT/burst, surge, conducted RF, power-frequency immunity; conducted and radiated emissions
Mounting
Panel (flush) mounting; NSA3 depth 235 mm, NSA2 225 mm, plus ≥ 80 mm for rear wiring

Documentation and support

  • PDF NSA3 Smart Station Monitoring Unit — Technical ManualV2.0 · October 2026 · 636 KB Download
  • PDF NSA2 Smart Station Monitoring Unit — Technical ManualV2.0 · October 2026 · 582 KB Download
  • PDF NSA6000 Smart Station Monitoring Unit — Technical ManualV2.0 · October 2026 · 794 KB Download

MODBUS register maps and configuration software are available in Chinese on our download page. IEC 104 / IEC 61850 point lists and model files are available on request — email sales@aoyipower.com.

Warranty: 12 months from energization or 18 months from shipment, whichever comes first. Response within 2 hours and on site within 48 hours where required. Spare parts remain available for all three product generations.

Talk to our engineers

Model selection, technical proposals or quotations — we usually reply within one business day.

Emailsales@aoyipower.com
Phone+86 10 8646 1328